Ian Caddy wrote:


Jay Monkman wrote:
<snip>


That's a real waste of CPU time. You'll end up spending a significant amount of
time in interrupt processing.
10ms is the default tick rate for RTEMS, and a pretty standard tick rate for
other OSes. Until recently, that was the rate for Linux on x86.




We use a 1ms tick since our systems (Power Utilities) SCADA like 1ms resolution on all digital inputs and a lot of our timeouts are based on small millsecond times. This is on a 90MHz Coldfire processor with no dramas.

Most if not all of the systems I know that OAR has consulted on use either a 1 millisecond or 500 microsecond tick. FOr the 500 microsecond tick, the CPU has to be pretty fast and the application had to have good reason.


regards,

Ian Caddy




--
Joel Sherrill, Ph.D.             Director of Research & Development
joel@OARcorp.com                 On-Line Applications Research
Ask me about RTEMS: a free RTOS  Huntsville AL 35805