[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Problems connecting two embedded boards running RTEMS
- Date: Fri, 28 Jul 2006 07:52:16 +0800
- From: paulw at omnitronics.com.au (Paul Whitfield)
- Subject: Problems connecting two embedded boards running RTEMS
Joel Sherrill wrote:
> A.Jallad at surrey.ac.uk wrote:
>> Hi,
>>
>> I am trying to make a simple ethernet connection between two embedded
>> boards with a LEON processor running on each. I am trying to make a
>> connection between the two boards running RTEMS. The server starts
>> listening but the client fails to connect.
>> What irritates me most is that the connection works fine between a
>> Linux machine and each of the two boards individually in any
>> configuration (linux machine serving as server and RTEMS board as
>> client and vice-versa).
>>
>>
> Stupid question.. is it possible that both RTEMS boards are configured
> to use the same IP address?
>
Next stupid question ... is it possible that both RTEMS boards are
configured with the same ETHERNET address?
Paul
=========================================================================
The information in this e-mail is intended for the addressee only.
Unauthorised use, copying, disclosure or distribution by anyone else
is prohibited. Please let us know immediately if you receive this
e-mail in error. Thank you.
=========================================================================