Leon,
Leon Pollak schrieb:
> Well, the switch theory is clear.
> But isn't the first arp request enough for the switch to learn that RTEMS box
> has that MAC address? Actually, even the first arp "box to itself" should
> teach it were is it, no?
> Besides, IMHO, this can not explain the loss of INCOMING packet after two
> outgoing were sent and I saw them in my PC via the same switch.
Ok, this really points to the hardware reset at the "source" of the
problem, either inside the PHY or the MPC8260.
- Once again: After reset, the PHY has at least 5 seconds time for
auto-negotiation, before the ethernet traffic starts? This should be
ensured with the download time anyway...
- Can you possibly send me the source of the ethernet driver just to
double check, that everything is all right there?
wkr,
Thomas.
>
> Thanks!
>
--
--------------------------------------------