[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

a MODBUS port to RTEMS



Hello, every one.

    I have port a freeMODBUS to RTEMS. I have a very simple testing  in RTEMS 4.8.0 with a PC486 plateform, and it works OK.  I attached it here and maybe someone is interested in it. 

  TO build it :
      1. download freeMODBUS package  from it's website www.freemodbus.org, the version now is 1.3.0

       2. release freemodbus in a directory, and then build a new subdirectory "RTEMSi386" under the directory \demo

      3. release the atteched files in \demo\RTEMSi386?then MAKE it
      
  To test it?
        run \demo\RTEMSi386\o-optimize\MODBUS-demo.exe in a PC computer plateform, it will use COM port 1 as MODBUS port. the serial port setting is : 38400,8,E,1, no hardware flow control; and MODBUS address is 0x01;

        the demo can only response for Input registers, there are 4 registers which start address is 0x1000.

    
       Enjoy it, thank you.

 

_________________________________________________________________
?????????live mail????????